POWER AVAILABILITYSeries 600T™ UPS INSTALLATION MANUALSingle ModuleThree-Phase65-225 kVA60 Hz
4 Installation Manual5. EQUIPMENT LOCATION1. Handle cabinet(s) in accordance with WARN-INGS in Section 3. Use a suitable material handling device to
Liebert Series 600T UPS, 65-225 kVA, Single Module 5BATTERY SAFETY PRECAUTIONS IN FRENCH PER CSA REQUIREMENTSINSTRUCTIONS IMPORTANES CONCERNANT LA SÉC
6 Installation Manual6.2 Battery CabinetsOptional battery cabinets are available from Liebert and other qualified vendors. Consult your submittal pack
Liebert Series 600T UPS, 65-225 kVA, Single Module 76.3 Open-Rack BatteriesWhen batteries other than Liebert Battery Cabinets are used, a remote batte
8 Installation ManualFigure 1. Preferred Grounding Configuration, 480 or 600 VAC input and outputGROUNDINGELECTRODEPER NEC 250-247.1. Preferred Ground
Liebert Series 600T UPS, 65-225 kVA, Single Module 9Figure 2. Alternative Grounding Configuration, 480 or 600 VAC input and output7.2 Alternative Grou
10 Installation ManualFigure 3. Preferred Grounding Configuration, 480 or 600 VAC input and 208 VAC outputGROUNDINGELECTRODEPER NEC 250-24LOCAL GROUND
Liebert Series 600T UPS, 65-225 kVA, Single Module 11Figure 4. Preferred Grounding Configuration, 208 VAC input and outputGROUNDINGELECTRODEPER NEC 25
12 Installation ManualFigure 5. Preferred Grounding Configuration with Ungrounded Delta Source Input (top) and Corner-Grounded Delta (bottom)GROUNDING
Liebert Series 600T UPS, 65-225 kVA, Single Module 13Figure 6. Preferred Grounding Configuration, Power-Tie™ SystemsGROUNDINGELECTRODEPER NEC 250-24GR
The following WARNING applies to all battery cabinets supplied with UPS systems:INTERNAL BATTERY STRAPPING MUST BE VERIFIED BY MANU-FACTURER PRIOR TO
14 Installation ManualFigure 7. Preferred Battery Cabinet Grounding ConfigurationGROUNDINGELECTRODEPER NEC 250-24TO OUTPUTDISTRIBUTION7.7. Preferred G
Liebert Series 600T UPS, 65-225 kVA, Single Module 158. WIRING CONSIDERATIONS8.1. Power WiringRefer to Site Planning Data (Appendix A) and the install
16 Installation ManualFigure 8. Typical One-Line Diagrams for SMS with Standard Dual InputCB3CB2CB1CB3CB2CB1Input IsoTransformerStandard SMS, with 208
Liebert Series 600T UPS, 65-225 kVA, Single Module 17Figure 9. Typical One-Line Diagrams of SMS with optional single input. CB3CB2CB1Input IsolationTr
18 Installation ManualFigure 10. Typical One-Line Diagrams of SMS with optional Maintenance Bypass CabinetsAbbreviations for Circuit BreakersBIBMBB By
Liebert Series 600T UPS, 65-225 kVA, Single Module 198.2. Control WiringControl wiring must be stranded and tinned and run in individual separate stee
20 Installation Manual9. WIRING CONNECTIONS9.1 WarningsDANGERVERIFY THAT ALL INCOMING HIGH AND LOW VOLTAGE POWER CIRCUITS ARE DE-ENERGIZED AND LOCKED
Liebert Series 600T UPS, 65-225 kVA, Single Module 21NOTEDC power and battery circuit breaker con-trol cables are provided with the Liebert brand Batt
22 Installation ManualUse 75°C copper wire. Select wire size based on the ampacities in Table 310-16 and associated notes of the National Electrical C
Liebert Series 600T UPS, 65-225 kVA, Single Module 23NOTES:1. Manufacturer: Thomas & Betts (T & B). (800) 862-8324Table 3Field-Supplied LugsON
iINSTALLATION MANUALTABLE OF CONTENTS1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 Installation ManualReprinted with permission from NEC 1999, NFPA 70, the National Electrical Code , Copyright 1998, National Fire Protection Associ
Liebert Series 600T UPS, 65-225 kVA, Single Module 25Figure 11. Outline Drawing Single and Multi Module 65 & 80 kVA
26 Installation ManualFigure 12. Outline Drawing, 100 through 225 kVA Module with SpaceSaver Top-Entry Configuration
Liebert Series 600T UPS, 65-225 kVA, Single Module 27Figure 13. Outline Drawing, 100 through 225 kVA Module with Standard Top & Bottom Entry
28 Installation ManualFigure 14. Bypass Transformer Cabinet, 65 & 80 kVA
Liebert Series 600T UPS, 65-225 kVA, Single Module 29Figure 15. Bypass Transformer Cabinet, 100-225 kVA
30 Installation ManualFigure 16. Battery Power Pack, 65 & 80 kVA
Liebert Series 600T UPS, 65-225 kVA, Single Module 31Figure 17. Battery Power Pack, Size A, 100-225 kVA
32 Installation ManualFigure 18. Outline Drawing, 3-Breaker MBC, 65 & 80 kVA
Liebert Series 600T UPS, 65-225 kVA, Single Module 33Figure 19. Outline Drawing, 3-Breaker MBC with Bypass Transformer, 65 & 80 kVA
TABLESTable 1. Power Wiring Terminals - Factory Supplied ...22Table 2. Tor
34 Installation ManualFigure 20. Outline Drawing, 3-Breaker MBC, 125-350 Amps
Liebert Series 600T UPS, 65-225 kVA, Single Module 35Figure 21. Outline Drawing, 3-Breaker MBC, 450 to 800 Amps
36 Installation ManualFigure 22. Outline Drawing, 3-Breaker MBC, 600-800 Amps
Liebert Series 600T UPS, 65-225 kVA, Single Module 37Figure 23. Line-up Detail, 65 & 80 kVA SMS with Bypass Transformer Cabinet
38 Installation ManualFigure 24. Line-up Detail, 100-225 kVA Space Saver with Bypass Transformer Cabinet
Liebert Series 600T UPS, 65-225 kVA, Single Module 39Figure 25. Line-up Detail, 100-225 kVA Standard SMS with Bypass Transformer Cabinet
40 Installation ManualFigure 26. Line-up Detail, 65 & 80 kVA SMS with Battery Cabinets
Liebert Series 600T UPS, 65-225 kVA, Single Module 41Figure 27. Line-up Detail, 100-225 kVA Space Saver with Battery Cabinets
42 Installation ManualFigure 28. Line-up Detail, 100-225 kVA Standard SMS with Battery Cabinets
Liebert Series 600T UPS, 65-225 kVA, Single Module 43Figure 29. Line-up Detail, 65 & 80 kVA with 3-Breaker MBC
iiiFigure 48. Option Wiring, Customer Alarm Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Fi
44 Installation ManualFigure 30. Line-up Detail, 65 & 80 kVA with Bypass Transformer and 3-Breaker MBC
Liebert Series 600T UPS, 65-225 kVA, Single Module 45Figure 31. Line-up Detail, 100-225 kVA Space Saver with 3-Breaker MBC
46 Installation ManualFigure 32. Line-up Detail, 100-225 kVA Space Saver with Bypass Transformer Cabinet and 3-Breaker MBC
Liebert Series 600T UPS, 65-225 kVA, Single Module 47Figure 33. Line-up Detail, 100-225 kVA with 3-Breaker MBC
48 Installation ManualFigure 34. Line-up Detail, 100-225 kVA with Bypass Transformer Cabinet and 3-Breaker MBC
Liebert Series 600T UPS, 65-225 kVA, Single Module 49Figure 35. Terminal Details, 65 & 80 kVA Single Module Systems
50 Installation ManualFigure 36. Terminal Details, 100 & 125 kVA Space Saver
Liebert Series 600T UPS, 65-225 kVA, Single Module 51Figure 37. Terminal Details, 150 & 225 kVA Standard SMS
52 Installation ManualFigure 38. Terminal Details, 100 & 125 kVA Standard SMS
Liebert Series 600T UPS, 65-225 kVA, Single Module 53Figure 39. Terminal Details, 150 & 225 kVA Standard SMS
54 Installation ManualFigure 40. Control Connection Locations, 65 & 80 kVA
Liebert Series 600T UPS, 65-225 kVA, Single Module 55Figure 41. Control Connection Locations, 100 through 225 kVA
56 Installation ManualFigure 42. Standard Control Wiring, Single Module System
Liebert Series 600T UPS, 65-225 kVA, Single Module 57Figure 43. Option Wiring, Alarm Status Contacts
58 Installation ManualFigure 44. Option Wiring, Maintenance Bypass Interlock
Liebert Series 600T UPS, 65-225 kVA, Single Module 59Figure 45. Option Wiring, Remote Status Panel Interface
60 Installation ManualFigure 46. Option Wiring, Remote Terminal IFM (RS-232 Communications)
Liebert Series 600T UPS, 65-225 kVA, Single Module 61Figure 47. Option Wiring, SiteScan Interface
62 Installation ManualFigure 48. Option Wiring, Customer Alarm Interface
Liebert Series 600T UPS, 65-225 kVA, Single Module 63Figure 49. Option Wiring, Battery Temperature Sensor
Liebert Series 600T UPS, 65-225 kVA, Single Module 11. SAFETY PRECAUTIONSRead this manual thoroughly, paying special attention to the sections that ap
64 Installation ManualFigure 50. Option Wiring, SNMP Interface
Liebert Series 600T UPS, 65-225 kVA, Single Module 65Figure 51. Option Wiring, Internal Modem
66 Installation ManualFigure 52. Option Wiring, Maintenance Bypass Cabinet
Liebert Series 600T UPS, 65-225 kVA, Single Module 67Figure 53. Module Battery Disconnect, 65 through 125 kVA
68 Installation ManualFigure 54. Module Battery Disconnect, 150 & 225 kVA
Liebert Series 600T UPS, 65-225 kVA, Single Module 69Figure 55. Remote Status Panel, Surface Mount
70 Installation ManualFigure 56. Circuit Breaker Schedule, 65 through 225 kVA
Liebert Series 600T UPS, 65-225 kVA, Single Module 71Figure 57. Circuit Breaker Schedule, Battery Cabinets, 65 to 500 kVA
72 Installation ManualFigure 58. Circuit Breaker Schedule, Maintenance Bypass Cabinet, 65 through 225 kVA
Liebert Series 600T UPS, 65-225 kVA, Single Module A-1Appendix A: Site Planning Data65-225 kVA Single Module SystemsNotes1. Nominal rectifier AC input
2 Installation Manual2. INSTALLATION CONSIDERATIONSInstall your Series 600T UPS in accordance with the submittal drawing package and the following pr
A-2 Installation ManualSeries 600T Single Module Systems208 Volt InputUPS RatingAC Output Voltage OptionsRectifier AC Input CurrentInverter Or By
Liebert Series 600T UPS, 65-225 kVA, Single Module A-3Series 600T Single Module Systems480 Volt InputUPS RatingAC Output Voltage OptionsRectifier A
A-4 Installation Manual Series 600T Single Module Systems600 Volt InputUPS RatingAC Output Voltage OptionsRectifier AC Input CurrentInverter Or By
Liebert Series 600T UPS, 65-225 kVA, Single Module A-5
The Company Behind the ProductsWith over a million installations around the globe,Liebert is the world leader in computer protectionsystems. Since its
Liebert Series 600T UPS, 65-225 kVA, Single Module 33. UNLOADING AND HANDLINGBecause the weight distribution in each UPS and ancillary cabinet is une
Comments to this Manuals